Start your EVOTECH request in under a minute.
TV Mount Subcontractor Jobs in Houston, TX 77079
North of I-10 the houses get older, larger and considerably less forgiving. Nottingham Forest, Wilchester, Yorkshire and the wooded streets around them are full of two-storey family rooms with stone chimney breasts running to the ceiling. EVOTECH IT LLC sends that work to experienced independent installers, and this page explains the standard it is judged against.
Memorial-area work gets judged on the finish, not the clock
In a lot of Houston, a television that is level, safe and working is a finished job. In 77079 that is the point at which the customer starts looking properly.
These are settled streets. The houses north of the freeway were largely built between the early sixties and the late seventies, most owners have been there a long time, and the neighbours talk. A wall you finish on a Tuesday in Wilchester gets shown to somebody on Saturday. That is genuinely how the work multiplies out here, and it is why we route these tickets narrowly.
What that standard means in practice, stated plainly so nobody is surprised:
- No visible patch. If a hole was made in the wrong place it gets repaired, sanded and textured to match, not filled and forgotten behind the screen.
- No slack cable anywhere. Not behind the panel, not looped on the floor behind the console, not zip-tied in a bundle on show.
- Nothing left leaning. Furniture goes back to the marks in the carpet, the hearth is wiped, and the dust from a masonry hole is vacuumed rather than brushed into the stone.
- The plate is level to a real level, checked after the panel is hung and the weight has settled, not before.
- You explain what you did. Which wall it is anchored to, what it is anchored with, and how the arm is meant to be moved.
We are not asking for artistry. We are asking for the standard a careful tradesman keeps in his own house, on every ticket, including the last one on a Friday.
Two-storey chimney breasts, pull-down arms and genuine weight
The signature room in this ZIP is a family room open to the second floor with a brick or stone chimney breast running the full height. It is a beautiful room and a demanding place to hang a screen.
The height argument
All that vertical masonry fools the eye into reading a very high screen as correct, and then the customer watches a film and their neck disagrees. The way out is usually a pull-down articulating mount that parks flat and high, then swings forward and drops in front of the mantel for viewing. Those brackets are heavy before the panel goes on them and they generate serious leverage at full extension. Know the rated capacity of what you are installing and be willing to tell a customer that the bracket they bought is not it.
Knowing what the chimney breast actually is
Two builds look identical from the sofa and behave nothing alike. A solid masonry breast carries whatever you anchor to it correctly, and every hole is permanent. Stone or brick veneer over framing is a skin that holds its own weight and very little else – the load has to reach the studs behind it, which means longer fasteners and knowing exactly how proud the facing sits. Get that wrong and the failure does not happen on the day you install it.
Working at height over a hearth
A raised stone hearth is a bad landing surface, and it sits directly below where you need to be. In these rooms that means a proper platform or a stand-off rather than the top step of a leaning ladder, and a second person on anything large enough to swing.
- Hammer drill, SDS bits and the right sleeve or wedge anchors for solid masonry – blown clean before setting.
- Lag bolts with real embedment into framing where the facing is veneer, never a drywall anchor supporting an arm.
- A panel dolly, straps and a helper for anything over roughly seventy inches or with the weight of a large pull-down bracket added.
- Torque you can feel rather than a drill clutch set by hope.
Where the cable goes when the customer will not accept seeing any
Concealment is close to the default expectation on these tickets, and it is the part that separates a fifteen-year installer from a fast one.
The houses here are almost all slab on grade with generous attics above. That geography decides your route more than anything the customer suggests. The attic is your friend; the slab is not, and a downward route to a first-floor outlet usually has to travel inside a framed wall or not at all.
Things that will decide the job:
- Fire blocking. Framing from this era frequently has horizontal blocking mid-height in exterior walls. Your glow rod stops, and how you deal with that without opening the wall in four places is the skill being paid for.
- Masonry means no in-wall route. Where the screen is going on solid stone, the cable comes down beside it, through a piece of trim, or the conversation becomes a remodel conversation. Nobody chases a chimney breast on a mounting ticket.
- Power is not a low-voltage cable. A power cord does not go inside a wall under any circumstances. Carry a listed in-wall power relocation kit or surface-mount the outlet, and never take a customer’s word that the last installer did it a different way.
- Two plates, top and bottom. Low-voltage plate behind the panel and another behind the console, so the next person to change a device does not need you.
- Patch and texture. If you open the wall, you close it properly. Bring compound, mesh, a sanding sponge and a texture can, and tell the customer honestly that paint matching is theirs.
- Remodels in progress. A fair number of these houses are being renovated. If the room is open, the right move is a call to dispatch to coordinate before the rock goes up – it is cheaper for the customer and a better wall for everyone.
What has to be true before your first Memorial ticket, and how to apply
EVOTECH IT LLC has run low-voltage work in west Houston since around 2004, holds a low-voltage contractor licence, carries insurance and is rated 5.0 stars. These tickets carry that reputation into rooms where it matters, so the requirements are firm.
- General liability in your own business name, with a certificate naming EVOTECH IT LLC as certificate holder, on file before anything is dispatched to you.
- Vehicle cover on what you drive to the job.
- A cleared background check, without exception. These are family homes and you will often be alone in them.
- No re-subcontracting. Bring help to lift; do not send a replacement.
- Our licence governs any cabling pulled or terminated on our behalf, and it is installed to our specification.
- Photographs on the ticket before you leave – the finished wall, and the anchoring while it is still visible on anything structural.
- Nothing priced on site. Added scope goes back through the office so the customer receives one written number from one company.
To apply, call (832) 359-2425 and ask for installer intake, or send the same through the contact page. Tell us how long you have been mounting, the heaviest panel and bracket combination you have installed and what you anchored it to, whether you conceal cable and how you handle fire blocking, whether you patch and texture your own openings, whether general liability is in force, and the days you will genuinely hold open.
Compensation is discussed at the interview and is set by the scope of the work and your experience. A tall-room pull-down over solid stone with concealed power is not the same job as a bedroom panel, and it will never be priced as though it were. This is independent contract work, not employment – you set your availability, you decide how the work is performed, and you remain responsible for your own taxes, tools and insurance.
Related services
Frequently asked questions
Am I expected to patch and texture after opening a wall?
Yes, to a standard that disappears under paint. Matching the paint itself is the homeowner’s job and we say so up front, but the drywall repair, the sanding and the texture are part of the work you were sent to do. Bring the materials with you – there is no shop run in the middle of a Memorial ticket.
Do new subcontractors get the fireplace and pull-down jobs straight away?
No. Those go to installers with a track record on our board, and the first one you run in this ZIP is alongside somebody of ours so we can look at the finished wall together. It is not a test of your pride, it is a two-hundred-pound assembly over a stone hearth in somebody’s family room.
Will I be working around other trades?
Often, in the renovation-heavy parts of this ZIP. Painters, electricians, cabinet fitters and the occasional interior designer. You coordinate politely, you do not commit us to anybody else’s schedule, and if another trade needs something from us you send it to dispatch rather than agreeing to it in a hallway.
How is compensation worked out when one job takes an entire morning?
By scope, agreed at the interview and confirmed on the ticket before you accept it. A job that involves height, masonry anchoring, concealed power and a repair is scoped as that job. You will know what a ticket carries before you say yes to it, which is the whole reason we do not publish a rate on a page.
What happens if I crack a stone face or damage a floor?
You tell us the same day and you tell the customer the truth in the room. That is what your general liability exists for, and a properly reported accident is a repair. A hidden one is the end of the working relationship, because we find out anyway – usually from the customer, which is the worst possible way.
If your finished walls stand up to daylight, we want to talk
Experienced installers who can handle tall rooms, stone anchoring and concealed wiring in the Memorial area should call (832) 359-2425 and ask for installer intake, or apply through the contact page. Compensation is agreed at the interview.
Book a Free Consultation
Ready for EVOTECH to help?
Before you leave, send the quick version. We will review the page you came from and reply with the clean next step.
