Moving a Memorial office to Cat6 without shutting the office down
Plenty of Memorial’s office space was wired well before Cat6 existed: mid-rise buildings along the Katy Freeway and Memorial Drive, professional suites near Memorial City and Town & Country, and small office buildings serving the Villages. Rewiring a suite that has to keep working is a migration project, not a pull-and-punch job. This is how EVOTECH plans one.
Start with a test, not a tear-out
Replacing cable that still performs is money spent for nothing; replacing cable that does not is money well spent. The only way to know which you have is to test a representative sample before deciding anything.
In older Memorial-area suites, what sits above the ceiling usually falls into one of these groups:
| What is in the ceiling | What it usually means | Typical recommendation |
|---|---|---|
| Cat5e that certifies to its own standard | Healthy for gigabit desks and phones | Keep it for those positions; add Cat6 only where new needs call for it |
| Original 1990s Cat5, or Cat3 telephone cable pressed into data service | Cat3 cannot carry modern Ethernet speeds; early Cat5 was never tested for everything gigabit relies on and is often marginal | Replace |
| Mixed, unlabeled runs left by several past tenants | Nobody knows what is live | Map before deciding, then remove what is abandoned |
| Links failing wire map or length | Damaged, mis-terminated or over the distance limit | Re-terminate when the cable is sound, replace when it is not |
| Cat5e feeding access points or PoE cameras | Works, but caps multi-gig access points | New Cat6 or Cat6A to those locations |
A partial upgrade is often the honest answer. A law or accounting practice whose Cat5e passes may need new cable only to its ceiling access points and a few printers, not to every desk.
What new cable will not fix
New Cat6 removes the cable as a suspect; it does not speed up anything else in the chain. If the switch ports are 10/100, every desk still connects at 100 Mb/s. If the internet circuit is the bottleneck, nothing inside the suite changes that. Slow Wi-Fi is far more often a matter of access-point placement, count and configuration than of the cable feeding each access point. And a switch bought to power a few phones may lack the PoE budget for new access points and cameras on top. During the walkthrough we note the switch model and its power budget and flag anything your IT provider should replace alongside the cable, so the upgrade delivers what the staff expect.
Mapping every live connection before anything is cut
The riskiest moment in an upgrade is cutting a cable nobody knew was doing something. Before new cable goes in, EVOTECH traces each existing jack to its panel port and switch port and records what is plugged into it. The inventory regularly turns up connections that are not ordinary Ethernet:
- an alarm panel’s communicator or a fax line riding on an old data cable
- card readers and door controllers that belong to building management, not the tenant
- a card terminal or postage meter on its own analog circuit
- a recorder or small server someone patched into the nearest wall jack years ago
Each one gets a line on a translation sheet: old jack ID, old panel port, what it serves, new jack ID, new panel port. That sheet is what makes the cutover fast, and it is the document your IT provider will want afterward. Anything owned by the building stays untouched until management says otherwise.
Installing the new Cat6 alongside the old plant
In an occupied office, the new network is built while the old one keeps running. New Cat6 patch panels go in beside the existing ones, or in a fresh rack section if there is room. New cable is pulled to each position and terminated in new jacks, usually in a new faceplate on the same box, or in an adjacent box when the old one is too crowded.
Ceiling work in occupied Memorial suites is generally planned for evenings, early mornings or weekends, and limited to the areas that can be opened and closed within one shift, with desks beneath open sections covered. Mid-rise buildings along the Katy Freeway frequently have hard drywall ceilings in corridors and lobbies; those need access openings, and their locations are agreed during the walkthrough.
Buildings from the 1970s and early 1980s deserve one more question before any tile is lifted: has the ceiling material, spray fireproofing or flooring mastic been surveyed for asbestos? Building managers usually keep a survey on file. If one does not exist, the survey comes first, because no crew should be disturbing suspect material on a guess.
Every new link is certified before cutover, not after. Finding a failed jack on a Tuesday afternoon, with the old plant still live, is a small fix. Finding it on a Monday morning after the old cable has been disconnected is an outage.
Old cable comes out once the new plant has proven itself in service. The electrical code calls for accessible abandoned cable to be removed rather than left in the ceiling, and taking it out frees the hooks and pathways the next project will need.
The cutover, step by step
- Confirm the starting point. Before the work window opens, your IT provider confirms that switch configurations are backed up and that reserved addresses for printers and other fixed devices are written down.
- Patch from the new panels into the same switch ports the translation sheet assigns, so VLANs and port settings carry across unchanged.
- Move devices from old outlets to new ones, desk by desk.
- Check every position: the phone registers, the computer receives an address and reaches the internet, printers print, readers and cameras report in.
- Leave the old patching labeled and disconnected, not removed, so any single position can be rolled back in a minute.
- Plan coverage for opening time. The first hour of a working day finds what a test sweep cannot, so someone who knows the job is reachable to fix it on the spot.
One drop or two at each desk?
Many offices wire one drop per desk and plug the computer into the back of the IP phone. It works, but the pass-through port on many phones runs at only 100 Mb/s, quietly capping the computer, and a phone reboot takes the computer offline with it. When the cable is being replaced anyway, a second drop per desk adds little to the job and separates the two. Gigabit-capable phones narrow the gap, so check the model before deciding.
Pricing an occupied-office upgrade, and where migrations go wrong
Items that change the quote:
- How many positions are replaced, and how many stay on tested existing cable
- After-hours and weekend work requirements
- Lay-in tile ceilings versus drywall ceilings needing access openings
- Plenum jacket where the ceiling returns air
- The volume of abandoned cable to remove
- New patch panels, rack space and cable management
- A single-weekend cutover versus phases by department
Where migrations go wrong:
- Disconnecting old cable before the new links are certified
- Cutting an alarm, fax or building-system circuit that was riding on a data cable
- Terminating new Cat6 on an existing Cat5e patch panel, which makes the link Cat5e
- Adding PoE access points and cameras without checking the switch’s power budget
- Leaving the retired panel unlabeled, so nobody can tell later which side is live
Request a Cat6 upgrade quote for your Memorial office
Related services
Frequently asked questions
Can we keep our existing patch panel and just replace the cable?
Every desk has a second cable that used to serve the phones. Can it be reused?
Will the upgrade leave patched holes in our walls?
How long does an occupied-office upgrade take?
Do you work in the Memorial Villages and around CityCentre?
Plan a Cat6 upgrade that never takes your Memorial office offline